In CADWorx Plant we can set the variable for showing the Pipe line continuation display for different line number in Isometric drawing output.

ImageGrafix Software FZCO - CADWorx Plant Setup

ImageGrafix Software FZCO - CADWorx Plant Pro Command 2

ISOGEN Continuation Graphics Count

Default value: 0
Allowed values: 0, 1, 2, or 3

Displays continuation graphics based on the following selections:

  • 0 – Display no continuation graphics when running ISOGEN.
  • 1 – Display one continuation graphic when running ISOGEN.
  • 2 – Display two continuation graphics when running ISOGEN.

3 – Displays three continuation graphics when running ISOGEN.

ImageGrafix Software FZCO - CADWorx Plant Pro Command 3